{"title":"Ready to Ship","description":"\u003cp\u003eFinished products, priced and in stock. Built, programmed, and tested in Pittsboro, North Carolina; ships from our workshop with direct support from the people who built it. Purchase orders accepted for approved accounts.\u003c\/p\u003e","products":[{"product_id":"compressor-controller","title":"Compressor Controller Model R","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eDigital bolt-on controller for reciprocating air compressors\u003c\/h2\u003e\n\u003cp\u003eReplaces the factory mechanical pressure switch and timer drain with active digital control. Pre-wired or component-kit options drop in on any reciprocating compressor 2 HP and up — no compressor modification.\u003c\/p\u003e\n\n\u003cdiv class=\"doe-claims\"\u003e\n  \u003cdiv class=\"doe-claim\"\u003e\n    \u003cspan class=\"doe-claim__num\"\u003e~23%\u003c\/span\u003e\n    \u003cspan class=\"doe-claim__label\"\u003ecompressor energy savings\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"doe-claim\"\u003e\n    \u003cspan class=\"doe-claim__num\"\u003e100%\u003c\/span\u003e\n    \u003cspan class=\"doe-claim__label\"\u003etank moisture reduction\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"doe-claim\"\u003e\n    \u003cspan class=\"doe-claim__num\"\u003e\u0026lt;12 mo\u003c\/span\u003e\n    \u003cspan class=\"doe-claim__label\"\u003etypical payback\u003c\/span\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"doe-attribution\"\u003eIndependently validated by Pecan Street Labs under DOE-funded protocol on 5–20 HP reciprocating compressors.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block prose-block--savings\" id=\"section-savings\"\u003e\n\u003ch3\u003eCalculate your savings\u003c\/h3\u003e\n\u003cp\u003eTwo tools that estimate what this controller actually pays you back: confirm utility-rebate eligibility for your service territory, and run an ROI calculation against your compressor's HP, run hours, and electricity rate.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"https:\/\/compressorcontroller.com\/utility-rebates\/\" target=\"_blank\" rel=\"noopener\"\u003eUtility rebates\u003c\/a\u003e\n\u003ca href=\"https:\/\/compressorcontroller.com\/compressor-controller-roi-calculator-estimate-air-compressor-energy-savings\/\" target=\"_blank\" rel=\"noopener\"\u003eROI calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhat it does that a $75 pressure switch can't\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Drain\u003c\/strong\u003e — reads ambient temperature and humidity, drains only when condensate has accumulated. No wasted pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized Drain Technology\u003c\/strong\u003e — expels condensate-laden air on demand using ambient\/humidity feedback. Tested by Pecan Street Labs under DOE protocol with 100% moisture reduction. In many installations it eliminates the need for a refrigerated air dryer entirely — and unlike no-air-loss drains it never clogs, unlike timer drains it never wastes pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Controllable Start\u003c\/strong\u003e — holds the unloader open a few seconds on startup, just enough for the pump to warm up before loading. Lowers inrush current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRupture Detection\u003c\/strong\u003e — halts the compressor if it detects a runaway leak. Saves the pump on a broken hose.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverheat \u0026amp; Overrun Halt\u003c\/strong\u003e — stops the compressor at 250 °F (121 °C) body or 30 minutes of continuous run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Alternation\u003c\/strong\u003e (Dual Pump) — balances pump wear within ~5 minutes over service life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor City link\u003c\/strong\u003e — one wire ties two controllers together for redundancy or CFM scaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-compare\"\u003e\n\u003ch3\u003eCompare editions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded\u003c\/th\u003e\n\u003cth\u003eController Only\u003c\/th\u003e\n\u003cth\u003eComponents Kit\u003c\/th\u003e\n\u003cth\u003ePre-Wired Bolt-on\u003c\/th\u003e\n\u003cth\u003ePre-Wired + 10 HP VFD\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Controller\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump temperature sensor\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temp \/ humidity sensor\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC–DC power supply\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuzzer \u0026amp; power rocker switch\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP67 enclosure\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounted sensors\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings, unloader, drain hardware\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e220 V valves\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory pre-wired \u0026amp; tested\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated 10 HP VFD\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003ePricing for each edition is in the right panel above. Choose Single Pump or Dual Pump in the Pump Configuration selector; Dual Pump is not available with the integrated VFD edition.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e 12 V DC, 2 W typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController:\u003c\/strong\u003e ATmega328p, 20 MIPS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 20×4 LCD with blue backlight, seven info screens\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure sensor:\u003c\/strong\u003e 304 stainless body, 1 % accuracy, \u0026lt;0.1 % FS\/year drift\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e −40 to +125 °C pump head; 0 to 50 °C ambient\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 6 relays, 10 A @ 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e DIP switches for °C\/°F, drain, fan, simplex\/duplex, master\/slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalytics:\u003c\/strong\u003e EEPROM stores lifetime hours, cycle count, fault history\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\"\u003e\n\u003ch3\u003eWho already installed it\u003c\/h3\u003e\n\u003cdiv class=\"logo-fader-block\"\u003e\n  \u003cdiv class=\"logo-fader-block__copy\"\u003e\n    \u003cp\u003eAutomotive paint and body shops, machine and CNC shops, cabinet and woodworking shops, fleet maintenance and tire shops, dental compressed-air rooms, light manufacturing, federal facilities, and dairy and farm operations — any continuous-duty reciprocating compressor where moisture, drift, or downtime cost money.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"logo-fader\" aria-label=\"Customers and partners\"\u003e\n    \u003cdiv class=\"logo-fader__slot\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/sikorsky.png?v=1777433904\" alt=\"Sikorsky\" loading=\"lazy\"\u003e\u003c\/div\u003e\n    \u003cdiv class=\"logo-fader__slot\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/firetron.png?v=1777433906\" alt=\"FireTron\" loading=\"lazy\"\u003e\u003c\/div\u003e\n    \u003cdiv class=\"logo-fader__slot\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/usaf.png?v=1777433909\" alt=\"U.S. Air Force\" loading=\"lazy\"\u003e\u003c\/div\u003e\n    \u003cdiv class=\"logo-fader__slot\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/whelen.png?v=1777433912\" alt=\"Whelen\" loading=\"lazy\"\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-integration\"\u003e\n\u003ch3\u003eHow it integrates\u003c\/h3\u003e\n\u003cp\u003eThe controller bolts onto reciprocating air compressors of any brand or age, single-pump or duplex, single-phase 120\/240 VAC or three-phase 208\/480 VAC. The pressure sensor (A) replaces the mechanical pressure switch and reads tank pressure to within 0.5 PSI across the operating range. The controller (E) drives the existing motor contactor (B) and steps in only when readings cross your set points, so the original starter, overload, and motor protection stay exactly where they are.\u003c\/p\u003e\n\u003cp\u003eThe smart drain (D) cycles on accumulated runtime, not a fixed timer, so it opens just long enough to clear condensate and closes before it bleeds tank pressure. The intercooler fan (F) is independently controlled when head temperature crosses threshold; the CompressorCity link (G) is a single-wire bus that lets multiple controllers share runtime, balance pump wear, and stand in for each other on failure.\u003c\/p\u003e\n\u003cp\u003eEvery variant uses the same operator interface, the same set-point structure, and the same diagnostic readout, so retraining is not part of the rollout. Installation runs about a working hour for a journeyman electrician with the existing panel still mounted; the supplied wiring harnesses bring labelled landings to every connection in the original control circuit.\u003c\/p\u003e\n\u003cp class=\"prose-block__figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/sam-2024-screenshot.png?v=1777502884\" alt=\"Compressor Controller integration diagram showing pressure sensor (A), motor contactor (B), drain valve (C, D), controller (E), intercooler fan (F), and CompressorCity link (G)\" loading=\"lazy\" width=\"1280\" height=\"800\"\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-network\"\u003e\n\u003ch3\u003eScale instantly with Compressor-City\u003c\/h3\u003e\n\u003cp\u003ePair two or more controllers over a single one-wire link to share runtime, balance pump wear, and add N+1 redundancy without buying a duplex unit. The bus auto-discovers nodes on power-up: no addressing, no DIP-switch configuration, no commissioning step beyond running the wire.\u003c\/p\u003e\n\u003cp\u003eEach controller publishes its runtime hours, head temperature, current draw, and fault state; each subscribes to the same data from its peers. The lead unit handles primary demand; lag units cycle in proportionally so no single pump accumulates disproportionate hours. The result is a bank that lasts longer per unit and recovers from a maintenance event without dropping the room below set-point.\u003c\/p\u003e\n\u003cp\u003eOn failure the system fails over, not off. The next-healthiest unit takes the call within one duty cycle and the failed unit is held out until a technician acknowledges the fault. The same hardware that runs a single 5 HP shop compressor scales to a four-unit 200 HP industrial bank without changing firmware or panel layout, across any mix of single-pump and duplex units and any inverter or VFD configuration in front of them.\u003c\/p\u003e\n\u003cp class=\"prose-block__figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/linking-compressors.png?v=1777502883\" alt=\"Four reciprocating air compressors of different sizes, each with a SAM Compressor Controller mounted, demonstrating Compressor-City multi-unit pairing.\" loading=\"lazy\" width=\"1024\" height=\"640\"\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill this work on my Quincy \/ Ingersoll‑Rand \/ Champion \/ FS‑Curtis compressor?\u003c\/summary\u003e\n  \u003cp\u003eYes — the controller is designed for any reciprocating air compressor 2 HP and up that uses a contactor-driven motor. It replaces the factory mechanical pressure switch and timer drain. Brand of the compressor doesn’t matter; what matters is that it’s reciprocating (not screw \/ rotary).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat’s the difference between Single Pump and Dual Pump?\u003c\/summary\u003e\n  \u003cp\u003eSingle Pump (R100) drives one compressor. Dual Pump (R200) drives two compressors with lead\/lag alternation, balancing pump wear within ~5 minutes over service life. Pick Dual Pump for duplex installations.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDo I need an electrician to install it?\u003c\/summary\u003e\n  \u003cp\u003ePre-Wired editions arrive factory-tested with the panel ready to mount; a competent person can complete the install in 2–3 hours. The Components Kit is bolt-and-wire on standard duplex panels — if you’re comfortable wiring a contactor, you can install it. Controller Only is for technically proficient users who source enclosure and valves independently.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat if my compressor is 230 V single phase?\u003c\/summary\u003e\n  \u003cp\u003eThe controller runs on 12 V DC from the included AC–DC power supply (110–220 VAC input). The relay outputs are rated 10 A @ 250 VAC and switch the existing motor contactor — the controller does not carry motor current itself, so 230 V 1Φ or 240\/480 V 3Φ is fine.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eCan I keep my existing pressure switch as a backup?\u003c\/summary\u003e\n  \u003cp\u003eYes. The controller’s relay outputs offer NO and NC contacts, so you can wire the mechanical switch in series as a fail-safe upper limit. Most installs disconnect the mechanical switch entirely once the controller is verified.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eHow long does install take?\u003c\/summary\u003e\n  \u003cp\u003eTwo to three hours for Pre-Wired editions. Components Kit installs typically run 3–5 hours including bolting the enclosure, mounting sensors, and wiring the existing contactor. The Quick Start Guide above walks the install step-by-step.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDoes the VFD edition qualify for utility rebates?\u003c\/summary\u003e\n  \u003cp\u003eMany U.S. utilities run custom industrial energy-efficiency rebates that cover compressed-air controls, often paying per kWh saved. Confirm eligibility with your utility or program ally; the integrated 10 HP VFD pairs cleanly with most rebate programs.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eCan I daisy-chain controllers across multiple compressors?\u003c\/summary\u003e\n  \u003cp\u003eYes — Compressor City is a one-wire master\/slave link between two controllers. You get cheap N+1 redundancy and CFM scaling without buying a duplex unit.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat happens at the end of the warranty?\u003c\/summary\u003e\n  \u003cp\u003e90-day parts and labor from \u003cstrong\u003edate of purchase\u003c\/strong\u003e. After that, replacement parts ship from Pittsboro, NC at standard pricing; ticket-based support continues at no charge. The controller has been in the field since 2017.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDo you ship internationally?\u003c\/summary\u003e\n  \u003cp\u003eU.S. shipping ships from Pittsboro, NC. International orders are case-by-case — \u003ca href=\"\/pages\/contact?product=compressor-controller\"\u003erequest a quote\u003c\/a\u003e with destination and Incoterm.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, North Carolina, USA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e IP67 rated (Components Kit, Pre-Wired Bolt-on, and Pre-Wired + VFD editions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure sensor body:\u003c\/strong\u003e 304 stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-installed by:\u003c\/strong\u003e the included Quick Start Guide is written for an industrial maintenance technician or competent installer; the User Manual covers full configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 90 days parts and labor from date of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=compressor-controller\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-install\"\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cdiv class=\"install-split\"\u003e\n  \u003cdiv class=\"install-split__video\"\u003e\n    \u003cdiv class=\"install-video-wrap\"\u003e\n      \u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/taw5RJnbA9w?rel=0\u0026amp;modestbranding=1\" title=\"Compressor Controller installation walkthrough\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen loading=\"lazy\"\u003e\u003c\/iframe\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"install-split__steps\"\u003e\n    \u003col\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePower off the compressor\u003c\/strong\u003e at the disconnect; verify the contactor is de-energized.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMount the enclosure\u003c\/strong\u003e within reach of the contactor (Pre-Wired editions: just bolt and run conduit).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eWire the AC–DC supply\u003c\/strong\u003e from the supply side of the contactor to the controller's 12 V DC input.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eLand the relay outputs\u003c\/strong\u003e on the contactor coil terminals (replacing the mechanical pressure switch).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMount the sensors:\u003c\/strong\u003e pressure into the receiver tap; pump-head temp on the cylinder head; ambient near the intake.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eSet DIP switches\u003c\/strong\u003e for °C\/°F, simplex\/duplex, drain on\/off, fan on\/off.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePower on, verify\u003c\/strong\u003e pressure setpoints and run a short cycle. The Quick Start Guide details every step.\u003c\/li\u003e\n    \u003c\/ol\u003e\n    \u003cp class=\"install-split__time\"\u003eTypical install: \u003cstrong\u003e2–3 hours\u003c\/strong\u003e for Pre-Wired editions, \u003cstrong\u003e3–5 hours\u003c\/strong\u003e for Components Kit.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003e90-day parts-and-labor warranty from \u003cstrong\u003edate of purchase\u003c\/strong\u003e. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/Compressor-Controller-Brochure.pdf?v=1777340251\" target=\"_blank\" rel=\"noopener\"\u003eBrochure\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/R100-R200-Quick-Start-Guide.pdf?v=1777340254\" target=\"_blank\" rel=\"noopener\"\u003eQuick Start Guide\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/CCR100-CCR200-User-Manual.pdf?v=1777345909\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/CompressorController-VFD-Supplement.pdf?v=1777405142\" target=\"_blank\" rel=\"noopener\"\u003eVFD Supplement\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Single Pump \/ Controller Only Kit","offer_id":43842267545797,"sku":"CC-SP-CTRL","price":783.33,"currency_code":"USD","in_stock":true},{"title":"Single Pump \/ Components Kit","offer_id":43842267578565,"sku":"CC-SP-COMP","price":1283.33,"currency_code":"USD","in_stock":true},{"title":"Single Pump \/ Pre-wired Bolt-on Kit","offer_id":46135638065349,"sku":"CC-SP-PWBO","price":1733.33,"currency_code":"USD","in_stock":true},{"title":"Single Pump \/ Pre-Wired with Components Kit and Integrated 10HP VFD","offer_id":46135638098117,"sku":"CC-SP-VFD","price":3256.15,"currency_code":"USD","in_stock":true},{"title":"Dual Pump \/ Controller Only Kit","offer_id":46135638130885,"sku":"CC-DP-CTRL","price":967.21,"currency_code":"USD","in_stock":true},{"title":"Dual Pump \/ Components Kit","offer_id":46135638163653,"sku":"CC-DP-COMP","price":1517.21,"currency_code":"USD","in_stock":true},{"title":"Dual Pump \/ Pre-wired Bolt-on Kit","offer_id":46135638196421,"sku":"CC-DP-PWBO","price":1967.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/R100_Compressor_Controller.jpg?v=1732243435"},{"product_id":"bolt-on-pump-temperature-sensor-replacement-dtb360-r1-r2","title":"Bolt-On Pump Temperature Sensor (DTB360, R1\/R2 replacement)","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eBolt-on pump-head temperature sensor — DTB360 R1\/R2 replacement\u003c\/h2\u003e\n\u003cp\u003eDirect replacement for the pump-head temperature sensor supplied with R1 and R2 Compressor Controller kits. Bolts to the cylinder head, plugs into the controller's temperature input, no recalibration needed.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhy order this\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect-replacement spare\u003c\/strong\u003e for the temperature sensor that ships with the Compressor Controller R1 \/ R2 kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBolt-on mounting\u003c\/strong\u003e — stainless tab seats on the cylinder head; no thermal-paste fiddling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-play\u003c\/strong\u003e with the SAM controller's temperature input — no recalibration, no DIP-switch changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible coverage range:\u003c\/strong\u003e −40 to +125 °C, matching the controller spec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor type:\u003c\/strong\u003e bolt-on pump-head temperature probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range:\u003c\/strong\u003e −40 to +125 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e stainless tab, cylinder-head bolt-on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e SAM Compressor Controller R1, R2, and Model R kits (Single Pump and Dual Pump)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e harness with controller-side connector (matches factory pinout)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, NC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill it work with my Model R \/ Single Pump or Dual Pump kit?\u003c\/summary\u003e\n  \u003cp\u003eYes. The DTB360 is the same temperature sensor used across the R1, R2, and current Model R kit lineup, so it drops in identically.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDo I need to recalibrate the controller?\u003c\/summary\u003e\n  \u003cp\u003eNo — the sensor matches the controller's expected sensor characteristics out of the box. Plug it in and resume operation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDo I need this if my kit is brand new?\u003c\/summary\u003e\n  \u003cp\u003eNo — this is a service \/ spare item. Order if your existing pump-head sensor has failed or you need a redundant spare.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Assembled in Pittsboro, North Carolina, USA. Components are sourced from global suppliers; final assembly, firmware, and QC happen in the NC workshop.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=bolt-on-pump-temperature-sensor-replacement-dtb360-r1-r2\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; certifications:\u003c\/strong\u003e available on request — \u003ca href=\"\/pages\/contact?product=bolt-on-pump-temperature-sensor-replacement-dtb360-r1-r2\"\u003eopen a ticket\u003c\/a\u003e for the current scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eFull technical datasheet, installation guide, and warranty terms are available on request. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"\/pages\/contact?product=bolt-on-pump-temperature-sensor-replacement-dtb360-r1-r2\"\u003eRequest datasheet\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=bolt-on-pump-temperature-sensor-replacement-dtb360-r1-r2\u0026amp;type=quote\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44193618133189,"sku":"DTB360","price":47.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/tempsensor.jpg?v=1730673289"},{"product_id":"sam-wood-stove-boiler-optimization-controller","title":"SAM Wood Stove \u0026 Boiler Optimization Controller","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eOptimization controller for wood stove, pellet stove, and outdoor wood boiler installations\u003c\/h2\u003e\n\u003cp\u003eBolt-on controller that converts a manual-damper \/ thermostat-only setup into closed-loop combustion control. Continuously reads the system state and adjusts damper, blower, or feed-rate to hold the target output without the chimney-loss \/ creosote \/ overheating tradeoffs of running open-loop. Pre-configured kit — no ladder programming.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhy this controller vs. the conventional setup\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated closed-loop adjustment\u003c\/strong\u003e — damper \/ blower \/ feed-rate control based on temperature feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-point temperature sensing\u003c\/strong\u003e — combustion-zone, outlet, and ambient sensors keep the controller in the loop on actual stove state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure monitoring\u003c\/strong\u003e — for hydronic boiler installs (closed water loop).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety interlocks\u003c\/strong\u003e — over-temperature, runaway combustion, and pressure-excursion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor and outdoor compatible\u003c\/strong\u003e — freestanding indoor wood stoves, pellet stoves, and outdoor wood boilers feeding hydronic systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-configured kit\u003c\/strong\u003e — fast setup, no ladder logic, no control-theory expertise required to install.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e wood stove, pellet stove, outdoor wood boiler\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl modes:\u003c\/strong\u003e closed-loop damper \/ blower \/ feed-rate based on temperature feedback\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing:\u003c\/strong\u003e multi-point temperature; pressure (boiler installs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e over-temperature, runaway combustion, pressure-excursion interlocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor\/outdoor:\u003c\/strong\u003e both supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm factor:\u003c\/strong\u003e pre-configured kit, fast setup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e full specifications (sensor count, output channels, supported stove brands, hydronic loop interface, electrical input) available on request — \u003ca href=\"\/pages\/contact?product=sam-wood-stove-boiler-optimization-controller\"\u003econtact us\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill it work with my specific stove or boiler brand?\u003c\/summary\u003e\n  \u003cp\u003eThe controller is brand-agnostic for the underlying control variables (damper actuator, blower, feed motor, temperature\/pressure sensors). For brand-specific compatibility — especially pellet-system auger \/ ash-removal integration — \u003ca href=\"\/pages\/contact?product=sam-wood-stove-boiler-optimization-controller\"\u003econtact us\u003c\/a\u003e with your stove\/boiler model and we'll confirm fit.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDoes it work with hydronic outdoor wood boilers?\u003c\/summary\u003e\n  \u003cp\u003eYes. Pressure monitoring on the closed water loop is built in. Confirm pump-control \/ zone-valve interface with us before ordering.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill it reduce my fuel use?\u003c\/summary\u003e\n  \u003cp\u003eClosed-loop combustion control consistently outperforms manual-damper operation on every fuel-loss vector: chimney loss, incomplete combustion, and overheating in mild weather. We don't publish a numeric percentage without source-doc verification — the magnitude depends heavily on your stove, fuel, and operator habits.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eIs this a consumer product?\u003c\/summary\u003e\n  \u003cp\u003eNo — this is OEM\/installer-grade. Installation requires hands-on wiring, sensor placement, and damper\/blower actuator setup. Serious off-grid \/ wood-heat homeowners with technical skill do install it directly; otherwise plan for an installer.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Assembled in Pittsboro, North Carolina, USA. Components are sourced from global suppliers; final assembly, firmware, and QC happen in the NC workshop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e residential and light-commercial wood \/ pellet combustion only — not for gas, electric, or industrial boilers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=sam-wood-stove-boiler-optimization-controller\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; certifications:\u003c\/strong\u003e available on request — \u003ca href=\"\/pages\/contact?product=sam-wood-stove-boiler-optimization-controller\"\u003eopen a ticket\u003c\/a\u003e for the current scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eFull technical datasheet, installation guide, and warranty terms are available on request. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"\/pages\/contact?product=sam-wood-stove-boiler-optimization-controller\"\u003eRequest datasheet\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=sam-wood-stove-boiler-optimization-controller\u0026amp;type=quote\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44193810940101,"sku":"SAM-WSBC","price":1485.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/controller1.jpg?v=1730565363"},{"product_id":"digital-water-pump-controller","title":"SAM Digital Water Pump Controller - OEM","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eDigital water pump controller for well, irrigation, and light-sewage installations\u003c\/h2\u003e\n\u003cp\u003ePre-wired IP67 controller that drops into an existing pressure-switch + dry-run-protection setup — or designed in by an OEM building their own pump product. Adds active fault detection, freeze protection, operating-hour tracking, and digital monitoring on top of the basic start\/stop logic.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhy this controller vs. the conventional setup\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 enclosure\u003c\/strong\u003e — rated for outdoor and wet-environment installation without secondary housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-wired harness\u003c\/strong\u003e — reduces field install time vs. building up a controller from discrete components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive fault detection\u003c\/strong\u003e — flags dry-run, freeze, and other off-nominal pump conditions instead of cycling silently into damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreeze protection\u003c\/strong\u003e — explicit cold-weather control logic for outdoor wellheads and exposed irrigation manifolds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating-hour and cycle tracking\u003c\/strong\u003e — for maintenance planning and warranty claims.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring and reporting\u003c\/strong\u003e — live-status indicators on the controller; remote-monitoring options available on request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm factor:\u003c\/strong\u003e pre-wired IP67 controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure rating:\u003c\/strong\u003e IP67\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication range:\u003c\/strong\u003e water-well pumps (submersible \/ above-ground), irrigation systems, light-sewage installs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault detection:\u003c\/strong\u003e dry-run, freeze, additional off-nominal conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTracking:\u003c\/strong\u003e operating hours and cycle count\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e full specifications (input voltage, pump compatibility, sensor inputs, control outputs, dimensions) available on request — \u003ca href=\"\/pages\/contact?product=digital-water-pump-controller\"\u003econtact us\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eHow is this different from the dedicated Sewage Pump Controller?\u003c\/summary\u003e\n  \u003cp\u003eThis SKU is the general-purpose water\/irrigation\/light-sewage controller. For dedicated sewage installs (lift stations, septic systems, heavy-duty wastewater), the \u003ca href=\"\/products\/sam-sewage-pump-controller-oem\"\u003eSAM Sewage Pump Controller\u003c\/a\u003e adds float-switch fault awareness and sewage-tuned reliability features.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill this work with my existing pump?\u003c\/summary\u003e\n  \u003cp\u003eIt's designed to drop into an existing pressure-switch + dry-run-protection setup. Confirm input voltage, pump HP, and connector format with us before ordering — we'll match the harness.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eIs remote monitoring included?\u003c\/summary\u003e\n  \u003cp\u003eLive-status indicators are on the controller itself. Remote \/ connected monitoring is available as an add-on — \u003ca href=\"\/pages\/contact?product=digital-water-pump-controller\"\u003econtact us\u003c\/a\u003e for the current options.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eIs the price the same for OEM volume?\u003c\/summary\u003e\n  \u003cp\u003e$1,485 is the published single-unit price. Volume \/ OEM pricing is available on PO — reach out with quantity and target install date.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Assembled in Pittsboro, North Carolina, USA. Components are sourced from global suppliers; final assembly, firmware, and QC happen in the NC workshop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e IP67 rated for wet-environment outdoor installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=digital-water-pump-controller\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; certifications:\u003c\/strong\u003e available on request — \u003ca href=\"\/pages\/contact?product=digital-water-pump-controller\"\u003eopen a ticket\u003c\/a\u003e for the current scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eFull technical datasheet, installation guide, and warranty terms are available on request. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"\/pages\/contact?product=digital-water-pump-controller\"\u003eRequest datasheet\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=digital-water-pump-controller\u0026amp;type=quote\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44195254075589,"sku":"SAM-DWPC-OEM","price":1485.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/water-well-controller.jpg?v=1730663241"},{"product_id":"sam-sewage-pump-controller-oem","title":"SAM Sewage Pump Controller - OEM","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eDigital sewage pump controller, scoped specifically for wastewater\u003c\/h2\u003e\n\u003cp\u003ePre-wired IP67 controller for sewage and wastewater pump installations. Distinct from the generic water-pump controller by dedicated float-switch fault-awareness logic and sewage-tuned reliability features. Optional remote \/ wireless monitoring available for installations where silent cycling into a failure is unacceptable.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhy this controller vs. the conventional setup\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat-switch fault awareness\u003c\/strong\u003e — detects a jammed or failed float and flags it instead of silently cycling into a sewage backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry-run protection\u003c\/strong\u003e — stops the pump before an empty-sump run damages the impeller or seals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-time monitoring\u003c\/strong\u003e — continuous pump-operation tracking so faults surface in real time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 enclosure\u003c\/strong\u003e — rated for sewage-adjacent wet environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating-hour and cycle tracking\u003c\/strong\u003e — for maintenance planning and warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional remote \/ wireless monitoring\u003c\/strong\u003e — available as an add-on for lift stations and remote-site installs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm factor:\u003c\/strong\u003e pre-wired IP67 sewage pump controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure rating:\u003c\/strong\u003e IP67\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e dedicated sewage \/ wastewater installations — submersible or dry-pit, lift stations, septic and commercial sewage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat-switch logic:\u003c\/strong\u003e active fault-detection topology (vs passive continuity)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry-run protection:\u003c\/strong\u003e impeller \/ seal protection on empty-sump conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTracking:\u003c\/strong\u003e operating hours and cycle count\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e full specifications (input voltage, pump compatibility, float-switch wiring, remote-monitoring protocol, dimensions) available on request — \u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\"\u003econtact us\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eHow is this different from the standard Digital Water Pump Controller?\u003c\/summary\u003e\n  \u003cp\u003eThe sewage version adds dedicated float-switch fault-awareness logic and reliability features tuned for sewage \/ wastewater duty cycles. For wells, irrigation, and light-water duty, see the \u003ca href=\"\/products\/digital-water-pump-controller\"\u003eDigital Water Pump Controller\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat lift-station configurations are supported?\u003c\/summary\u003e\n  \u003cp\u003eThe base unit covers single-pump submersible and dry-pit sewage installations. For duplex (lead\/lag) lift stations, multi-float topologies, or remote \/ wireless reporting, contact us — specific configurations may be add-ons or custom.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eAre optional remote-monitoring features extra?\u003c\/summary\u003e\n  \u003cp\u003eYes — the live-store $1,485 base price includes the controller; remote \/ wireless monitoring is available as an add-on for installs that need it.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill this work with my existing float switches?\u003c\/summary\u003e\n  \u003cp\u003eIt supports the typical mechanical and mercury-bulb float topologies used on sewage pumps. Confirm switch count and wiring with us before ordering — we'll match the harness.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Assembled in Pittsboro, North Carolina, USA. Components are sourced from global suppliers; final assembly, firmware, and QC happen in the NC workshop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e IP67 rated for sewage-adjacent wet environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; certifications:\u003c\/strong\u003e available on request — \u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\"\u003eopen a ticket\u003c\/a\u003e for the current scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eFull technical datasheet, installation guide, and warranty terms are available on request. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\"\u003eRequest datasheet\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\u0026amp;type=quote\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44195258073285,"sku":"SAM-SPC-OEM","price":1485.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/sam-sewage-pump-controller.jpg?v=1730663091"},{"product_id":"sam-pcb-controllers-conveyor-controller-oem","title":"SAM PCB Controllers Conveyor Controller - OEM","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eConveyor controller and PLC-replacement platform — SMEMA-9851 compatible\u003c\/h2\u003e\n\u003cp\u003eDIN-rail conveyor controller with conveyor logic in place out of the box. Built for PCB-handling conveyors first but applicable to general indoor conveyor automation where a Siemens \/ Allen-Bradley \/ Mitsubishi PLC is overkill — both in cost and in ladder-programming complexity.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhy this controller vs. the conventional setup\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPC-SMEMA-9851 compatibility\u003c\/strong\u003e — drops into existing PCB production lines that expect the standard SMEMA handshake between machines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor logic in place\u003c\/strong\u003e — ships ready-configured. No ladder-diagram development cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBidirectional operation\u003c\/strong\u003e — runs forward and reverse under program control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated stepper motor drivers\u003c\/strong\u003e — no external driver module needed for the supported motor spec; less wiring, simpler maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBasic and advanced configurations\u003c\/strong\u003e — two tiers; advanced unlocks broader scope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-rail mount\u003c\/strong\u003e — installs in standard industrial control cabinets alongside existing equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit-friendly\u003c\/strong\u003e — deploys into existing indoor lines without rebuilding the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm factor:\u003c\/strong\u003e DIN-rail industrial controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication scope:\u003c\/strong\u003e PCB-handling conveyor + general indoor conveyor automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSMEMA compatibility:\u003c\/strong\u003e IPC-SMEMA-9851\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive:\u003c\/strong\u003e bidirectional, integrated stepper motor drivers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurations:\u003c\/strong\u003e basic and advanced tiers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount:\u003c\/strong\u003e DIN-rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e full specifications (stepper-driver current rating, I\/O count, input voltage, communication interfaces, exact tier deltas) available on request — \u003ca href=\"\/pages\/contact?product=sam-pcb-controllers-conveyor-controller-oem\"\u003econtact us\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhy this instead of a generic PLC?\u003c\/summary\u003e\n  \u003cp\u003eConveyor logic is in place out of the box — no ladder-diagram development cycle. The engineering time required to ladder-program a generic PLC for a typical PCB conveyor often exceeds the cost of this unit.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat's the SMEMA implementation?\u003c\/summary\u003e\n  \u003cp\u003eIPC-SMEMA-9851 compatible, the standard handshake protocol between PCB-line machines. Drops into existing SMEMA-aware lines without protocol-adapter intermediates.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat's the difference between basic and advanced?\u003c\/summary\u003e\n  \u003cp\u003eBoth ship with the conveyor + SMEMA logic. The advanced tier extends I\/O count, monitoring options, and configuration flexibility. \u003ca href=\"\/pages\/contact?product=sam-pcb-controllers-conveyor-controller-oem\"\u003eContact us\u003c\/a\u003e with your application and we'll recommend a tier.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eCan I use it for non-PCB conveyors?\u003c\/summary\u003e\n  \u003cp\u003eYes — the SMEMA layer is optional. It's deployable for general indoor material-handling conveyors. Outdoor \/ harsh-environment installs and heavy-industrial 3-phase VFD-driven conveyors are out of scope — this is DIN-rail, indoor, stepper-driven.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eIs this a quote-only or direct-buy SKU?\u003c\/summary\u003e\n  \u003cp\u003eDirect-buy via Shopify checkout is enabled at the published price. For volume orders, advanced-tier scoping, or installation support, we'll switch you to a quote flow.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Assembled in Pittsboro, North Carolina, USA. Components are sourced from global suppliers; final assembly, firmware, and QC happen in the NC workshop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount:\u003c\/strong\u003e DIN-rail; indoor industrial control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=sam-pcb-controllers-conveyor-controller-oem\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; certifications:\u003c\/strong\u003e available on request — \u003ca href=\"\/pages\/contact?product=sam-pcb-controllers-conveyor-controller-oem\"\u003eopen a ticket\u003c\/a\u003e for the current scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eFull technical datasheet, installation guide, and warranty terms are available on request. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"\/pages\/contact?product=sam-pcb-controllers-conveyor-controller-oem\"\u003eRequest datasheet\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=sam-pcb-controllers-conveyor-controller-oem\u0026amp;type=quote\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44195272589509,"sku":"SAM-CONVCTRL-OEM","price":5287.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/conveyor-controller-side-view.jpg?v=1730663917"},{"product_id":"truelevel-cnc","title":"TrueLevel CNC","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eSolid-state digital monitor for CNC machine coolant sumps\u003c\/h2\u003e\n\u003cp\u003eReplaces float-based level sensors with a no-moving-parts digital level + dual-zone temperature sensor. Drives an existing tramp-oil skimmer on a computed schedule. Visible across a noisy shop floor via a 450 lumen RGB light bar. Installs in 30 minutes — no drilling, no machine downtime, no subscriptions.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhat it does that a float sensor can’t\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid-state level sensing\u003c\/strong\u003e — no moving parts, nothing to jam on long stringy chips, sludge, or tramp-oil layers. Measures the fluid body itself, so it works equivalently with oil-based and water-soluble coolants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-zone temperature\u003c\/strong\u003e — one probe at the top of the tank (cutting-zone hot return), one at the bottom (cold bacterial zone). A divergence between the two is useful signal on its own.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e450 lumen RGB light bar\u003c\/strong\u003e — color, position, and pulse pattern encode multiple metrics simultaneously. 180° viewing angle, readable across a crowded shop floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-line LCD on a magnetic mount\u003c\/strong\u003e — attaches anywhere ferrous on or near the machine. Shows level, both temperatures, skimmer status, alarm history.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Skimmer Control\u003c\/strong\u003e (Standard + Skimmer Output) — relay output with current-transformer feedback drives an existing tramp-oil skimmer on the controller’s computed schedule, not a dumb timer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHaas factory-port harness\u003c\/strong\u003e — drops into the stock Haas float-sensor connector. Existing Haas alarm \/ low-coolant logic sees TrueLevel like it sees the OEM float.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYou buy it. You own it.\u003c\/strong\u003e — no subscriptions, no SaaS license, no recurring fees, no cloud dependency. Sensor, controller, and light bar communicate locally.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-compare\"\u003e\n\u003ch3\u003eCompare editions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded\u003c\/th\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003cth\u003eStandard + Skimmer Output\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolid-state digital level sensor\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual-zone temperature monitoring\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e450 lumen RGB light bar\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-line LCD controller, magnetic mount\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal DC harness\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHaas factory-port connector option\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkimmer relay output + Current Transformer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect connection to stock Haas float-sensor connector\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003ePricing for each edition is in the right panel above. Pick the Skimmer Output edition if you have an existing tramp-oil skimmer to drive on the controller’s computed schedule.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor length:\u003c\/strong\u003e 9 in (22 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTank depth range:\u003c\/strong\u003e 2–9 in (5–22 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 12 V DC (24 V DC optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 4-line LCD, 20 characters per line\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight bar:\u003c\/strong\u003e 450 lumens, 180° viewing angle, 50,000+ hour lifespan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor body:\u003c\/strong\u003e synthesized nylon\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCord:\u003c\/strong\u003e 7.32 ft (2.23 m) retractable coil\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoolant compatibility:\u003c\/strong\u003e oil-based, water-soluble, synthetic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine compatibility:\u003c\/strong\u003e mills, lathes, grinders with a sump; 12 V DC tramp-oil skimmers (Skimmer Output edition)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e clip-mount sensor at the sump; magnetic LCD anywhere ferrous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eHow does this sensor not jam on aluminum chips?\u003c\/summary\u003e\n  \u003cp\u003eThe sensor is fully solid-state — no moving parts, no float. There is no physical mechanism for long stringy chips, sludge, or tramp-oil layers to jam. It measures the fluid body itself electrically.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eAre there any monthly subscription fees?\u003c\/summary\u003e\n  \u003cp\u003eNo. TrueLevel CNC is sold under a strict “You Buy It. You Own It.” model. Zero recurring fees, no SaaS subscription, no cloud account required. The device runs entirely locally.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill it mount easily to my specific machine tool?\u003c\/summary\u003e\n  \u003cp\u003eInstallation takes about 30 minutes, requires no machine downtime, and involves no drilling. The sensor uses a heavy-duty clip-mount at the sump; the LCD controller uses a magnetic mounting plate that attaches anywhere ferrous on or near the machine.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eCan it connect back to my Haas controller?\u003c\/summary\u003e\n  \u003cp\u003eYes. The included harness has an option for direct, factory-style connection into the stock Haas float-sensor port. Existing Haas alarm and low-coolant logic sees TrueLevel as if it were the OEM float sensor.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill this work with oil-based and water-soluble coolants?\u003c\/summary\u003e\n  \u003cp\u003eBoth. Because the sensor is solid-state and measures the fluid body itself, it works with oil-based, water-soluble, and synthetic coolants without recalibration.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eCan it run my existing tramp-oil skimmer?\u003c\/summary\u003e\n  \u003cp\u003eYes — the Standard + Skimmer Output edition includes a relay output with a current-transformer feedback loop. It actuates your existing skimmer motor on the controller’s computed schedule, not a dumb timer.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eHow does this save a shop money?\u003c\/summary\u003e\n  \u003cp\u003ePrimarily by reducing scrapped parts. When coolant runs hot, it stops displacing heat at the cutting zone — the part heats up, expands, and a tight-tolerance finishing pass comes out of spec after it cools. Catching the temperature spike on the RGB light bar before the finishing pass lets the operator pause, rebalance, and save the part.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eThrough-spindle-coolant only — no sump. Will this work?\u003c\/summary\u003e\n  \u003cp\u003eNo. TrueLevel monitors a coolant sump. Machines running exclusively through-spindle coolant at 1000+ psi without a sump are not the target use case.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat does the warranty cover?\u003c\/summary\u003e\n  \u003cp\u003e1-year parts and labor from \u003cstrong\u003edate of purchase\u003c\/strong\u003e. Ticket-based support is direct from the manufacturer in NC and continues at no charge after the warranty period.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDo you ship internationally?\u003c\/summary\u003e\n  \u003cp\u003eU.S. shipping ships from Pittsboro, NC. International orders are case-by-case — \u003ca href=\"\/pages\/contact?product=truelevel-cnc\"\u003erequest a quote\u003c\/a\u003e with destination and Incoterm.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, North Carolina, USA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor body:\u003c\/strong\u003e synthesized nylon, sized to survive a chip-heavy sump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight bar:\u003c\/strong\u003e 50,000+ hour rated lifespan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-installed by:\u003c\/strong\u003e the included owner’s manual is written for an industrial maintenance technician or competent installer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1 year parts and labor from date of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=truelevel-cnc\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-install\"\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower off the machine\u003c\/strong\u003e at the disconnect; pop the coolant tank lid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClip-mount the solid-state sensor\u003c\/strong\u003e at a clear point in the sump, away from heavy chip return paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetically mount the 4-line LCD\u003c\/strong\u003e anywhere ferrous on or near the machine where the operator can see it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount the RGB light bar\u003c\/strong\u003e high enough to be visible from operator stations across the cell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun the DC harness\u003c\/strong\u003e from the controller to a 12 V supply on the machine. Haas: drop the harness’s factory-port connector into the stock float-sensor port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(Skimmer Output only)\u003c\/strong\u003e wire the relay leads to the motor terminals of your existing tramp-oil skimmer; clip the current transformer around the same lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower on, verify\u003c\/strong\u003e level and dual-zone temperature on the LCD; confirm the light bar reflects current state. The owner’s manual walks every step.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"install-split__time\"\u003eTypical install: \u003cstrong\u003e30 minutes\u003c\/strong\u003e. No drilling. No machine downtime.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003e1-year parts-and-labor warranty from \u003cstrong\u003edate of purchase\u003c\/strong\u003e. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/Truelevel-CNC-Owners-Manual.pdf?v=1777351759\" target=\"_blank\" rel=\"noopener\"\u003eOwner’s Manual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Standard","offer_id":45475648176325,"sku":"TC-MA-STD","price":885.11,"currency_code":"USD","in_stock":true},{"title":"Standard + Skimmer Output","offer_id":45475648209093,"sku":"TC-MA-SKM","price":985.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/main-im-graphics.jpg?v=1764809545"},{"product_id":"digital-liquid-level-sensor-dev-kit-oem","title":"Digital Liquid Level Sensor Dev Kit - OEM","description":"\u003cp class=\"whitespace-pre-wrap break-words\"\u003eTransform your liquid monitoring with SAM Controllers' Digital Level Sensor - a breakthrough in solid-state sensing technology. Unlike traditional float sensors that can clog, jam, or fail, our digital sensor has no moving parts or open ports, delivering consistently accurate measurements for over 10 years. Each sensor combines precision level detection with dual temperature monitoring, providing complete tank awareness through digital feedback you can trust.\u003c\/p\u003e\n\u003cp class=\"whitespace-pre-wrap break-words\"\u003eThe real power lies in its versatility: from water tanks to chemical storage, our chemically-inert construction and I²C digital interface make integration seamless. With models ranging from 19\" to 69\" and precision stepping at 1.68\" intervals, you get granular level data without complexity. The included development unit and C libraries mean you can be up and running in hours, not weeks.\u003c\/p\u003e\n\u003cp class=\"whitespace-pre-wrap break-words\"\u003ePerfect for replacing unreliable float systems or upgrading analog sensors, our Digital Level Sensor delivers the accuracy of lab equipment with the durability of industrial hardware. Whether you're monitoring clean water or harsh chemicals, you get reliable readings every time - no maintenance, no calibration, no worries.\u003c\/p\u003e\n\u003ch2 class=\"font-600 text-xl font-bold\" level=\"2\"\u003eDevelopment Kit Includes\u003c\/h2\u003e\n\u003cul class=\"-mt-1 [li\u0026gt;\u0026amp;]:mt-2 list-disc space-y-2 pl-8\" depth=\"0\"\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"0\"\u003eSolid-state digital level sensor (DL series)\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"1\"\u003eDigital Level Development (DLD) interface unit\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"2\"\u003eComplete C libraries and sample code\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"3\"\u003eI²C communication protocol documentation\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"4\"\u003eIntegration guide and technical specifications\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"5\"\u003eMounting hardware kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"font-600 text-xl font-bold\" level=\"2\"\u003eKey Development Features\u003c\/h2\u003e\n\u003cul class=\"-mt-1 [li\u0026gt;\u0026amp;]:mt-2 list-disc space-y-2 pl-8\" depth=\"0\"\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"0\"\u003eI²C digital interface (100-400kHz)\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"1\"\u003e4KB NVRAM with user-accessible storage\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"2\"\u003eIntegrated dual temperature sensors\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"3\"\u003eFactory calibration data included\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"4\"\u003eReal-time operational feedback\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"5\"\u003eProgrammable status indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"font-600 text-xl font-bold\" level=\"2\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul class=\"-mt-1 [li\u0026gt;\u0026amp;]:mt-2 list-disc space-y-2 pl-8\" depth=\"0\"\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"0\"\u003eResolution: 1.68\" (42.2mm) steps\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"1\"\u003ePower: 5V DC, \u0026lt;15mA active\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"2\"\u003eCommunication: I²C with active feedback\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"3\"\u003eOperating temp: -25°C to +120°C\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"4\"\u003eAccuracy: ±0.1% measurement depth\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"5\"\u003eLife expectancy: 10+ years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"font-600 text-xl font-bold\" level=\"2\"\u003eAvailable Models\u003c\/h2\u003e\n\u003cul class=\"-mt-1 [li\u0026gt;\u0026amp;]:mt-2 list-disc space-y-2 pl-8\" depth=\"0\"\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"0\"\u003eModel20: 19.25\" (16.75\" measurement)\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"1\"\u003eModel40: 36\" (33.5\" measurement)\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"2\"\u003eModel60: 52.75\" (50.25\" measurement)\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"3\"\u003eModel80: 69.5\" (67\" measurement)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"whitespace-pre-wrap break-words\"\u003ePerfect for prototyping and development of:\u003c\/p\u003e\n\u003cul class=\"-mt-1 [li\u0026gt;\u0026amp;]:mt-2 list-disc space-y-2 pl-8\" depth=\"0\"\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"0\"\u003eIndustrial automation systems\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"1\"\u003eSmart tank monitoring\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"2\"\u003eProcess control applications\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"3\"\u003eEnvironmental monitoring\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words\" index=\"4\"\u003eCustom liquid level solutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"whitespace-pre-wrap break-words\"\u003e\u003cem\u003eCustom lengths and configurations available for production orders\u003c\/em\u003e\u003c\/p\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44195303227589,"sku":null,"price":3284.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/0-dldu-with-ddl-level_5263c3a8-6fe0-42a4-8b77-08d11b0805ae.jpg?v=1784158393"},{"product_id":"power-h-mini-dc-12a-h-bridge-driver-oem","title":"Power H Mini — 12A DC H-Bridge Driver (OEM)","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003e12A DC H-bridge driver module — compact, OEM-ready\u003c\/h2\u003e\n\u003cp\u003eBidirectional DC drive for prototype motors, actuators, and small reversible loads. Compact form factor scoped specifically for OEM integration where a full motor-driver evaluation board is over-spec'd. Designed and assembled in NC.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhat it does\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBidirectional DC drive\u003c\/strong\u003e — full H-bridge topology for motor reversal and bidirectional actuator control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12A continuous rating\u003c\/strong\u003e — covers small DC motors, linear actuators, and reversible solenoids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact form factor\u003c\/strong\u003e — sized for OEM integration into a finished product chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM scope\u003c\/strong\u003e — designed for engineers building a finished controlled product, not a single-board evaluation kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopology:\u003c\/strong\u003e H-bridge (full bridge, 4-quadrant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous current rating:\u003c\/strong\u003e 12 A DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e small DC motor reversal, linear actuator control, bidirectional solenoid \/ load drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm factor:\u003c\/strong\u003e compact OEM module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e full specifications (input voltage, PWM frequency, dimensions, control logic interface) available on request — \u003ca href=\"\/pages\/contact?product=power-h-mini-dc-12a-h-bridge-driver-oem\"\u003econtact us\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eIs this a stand-alone driver or does it need a controller?\u003c\/summary\u003e\n  \u003cp\u003eIt's a driver module — pair it with your own controller or microcontroller. PWM and direction inputs are exposed; the controller side is your design.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill 12A handle my motor?\u003c\/summary\u003e\n  \u003cp\u003e12A continuous fits most small DC motors and linear actuators. For peak \/ stall current draw, confirm your motor's locked-rotor spec is within tolerance — \u003ca href=\"\/pages\/contact?product=power-h-mini-dc-12a-h-bridge-driver-oem\"\u003econtact us\u003c\/a\u003e with the motor datasheet if in doubt.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eCan I use this with our development board?\u003c\/summary\u003e\n  \u003cp\u003eYes — the \u003ca href=\"\/products\/avr128db48devcan-development-board-curiosity-nano\"\u003eAVR128DB48devCAN dev board\u003c\/a\u003e exposes the PWM and GPIO needed to drive an external H-bridge. The TCD timer is well-suited to bidirectional motor PWM.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Assembled in Pittsboro, North Carolina, USA. Components are sourced from global suppliers; final assembly, firmware, and QC happen in the NC workshop.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=power-h-mini-dc-12a-h-bridge-driver-oem\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; certifications:\u003c\/strong\u003e available on request — \u003ca href=\"\/pages\/contact?product=power-h-mini-dc-12a-h-bridge-driver-oem\"\u003eopen a ticket\u003c\/a\u003e for the current scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eFull technical datasheet, installation guide, and warranty terms are available on request. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"\/pages\/contact?product=power-h-mini-dc-12a-h-bridge-driver-oem\"\u003eRequest datasheet\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=power-h-mini-dc-12a-h-bridge-driver-oem\u0026amp;type=quote\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44195310928069,"sku":"SAM-PHM-OEM","price":19.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/power-h-mini.jpg?v=1730675773"},{"product_id":"avr128db48devcan-development-board-curiosity-nano","title":"AVR128DB48devCAN Development Board (Curiosity Nano)","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eCuriosity Nano dev board with CAN integrated on the MCU\u003c\/h2\u003e\n\u003cp\u003eBuilt around the Microchip AVR128DB48 microcontroller with native classic CAN 2.0 on-die. No MCP2515, no TJA1050 transceiver shield, no SPI budget spent on CAN arbitration. Programmed via on-board USB-UPDI; works in Microchip Studio and MPLAB X with full step-debug, no external programmer.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhy this controller vs. the conventional setup\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN on the MCU\u003c\/strong\u003e — native classic CAN 2.0 controller on-die. Drop the MCP2515 from your prototyping stack; only a transceiver is needed for the physical layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCuriosity Nano form factor\u003c\/strong\u003e — familiar layout for AVR developers; on-board UPDI debugger over USB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix UARTs, two SPI, two I²C\u003c\/strong\u003e — broad peripheral mix for industrial protocol work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-chip OPAMP\u003c\/strong\u003e — local analog signal conditioning without discrete op-amp chips. Useful for pressure-transducer \/ load-cell prototypes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-Cross Detection\u003c\/strong\u003e — single-phase AC zero-cross handling without a separate comparator network. Pairs with the asynchronous TCD timer for triac \/ phase-control experiments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-bit DAC\u003c\/strong\u003e — analog setpoint output for closed-loop control prototypes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating range:\u003c\/strong\u003e 1.8–5.5 V — native interface to 3.3 V and 5 V logic without level shifters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMCU:\u003c\/strong\u003e Microchip AVR128DB48 (AVR core, 8-bit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlash \/ SRAM \/ EEPROM:\u003c\/strong\u003e 128 KB \/ 16 KB \/ 512 B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax clock:\u003c\/strong\u003e 24 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN:\u003c\/strong\u003e native, classic CAN 2.0 (CAN-FD not supported — AVR128DB48 family)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUART \/ USART:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPI:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI²C (TWI):\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog:\u003c\/strong\u003e on-chip OPAMP, Zero-Cross Detection, ADC with PGA, 12-bit DAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimers:\u003c\/strong\u003e TCA (16-bit), TCB (multiple), TCD (asynchronous, motor-control oriented)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming \/ debug:\u003c\/strong\u003e USB-UPDI on-board; full step-debug in Microchip Studio \/ MPLAB X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm factor:\u003c\/strong\u003e Curiosity Nano\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e full pinout, current budget, USB connector type, and Arduino board-manager URL available on request — \u003ca href=\"\/pages\/contact?product=avr128db48devcan-development-board-curiosity-nano\"\u003econtact us\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDoes this replace an MCP2515?\u003c\/summary\u003e\n  \u003cp\u003eYes. CAN is integrated into the MCU; no external SPI-to-CAN bridge needed. Only a transceiver is required for the physical layer.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDoes it support CAN-FD?\u003c\/summary\u003e\n  \u003cp\u003eNo — classic CAN 2.0 only. For CAN-FD, look at the AVR DU family or an ARM alternative.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eCan I use Arduino shields physically?\u003c\/summary\u003e\n  \u003cp\u003eHeaders are Arduino-compatible in layout. Library-level shield support depends on the AVR-core add-on you're using in the Arduino IDE (MegaCoreX, DxCore, or similar). Stick with Microchip Studio or MPLAB X if you need guaranteed AVR support.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eCan I step-debug?\u003c\/summary\u003e\n  \u003cp\u003eYes — full step debugging via the on-board UPDI interface in Microchip Studio or MPLAB X. No external debugger needed.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eIs this for production deployment?\u003c\/summary\u003e\n  \u003cp\u003eNo. Curiosity Nano format is for prototyping. Once your firmware is validated, lay out your own PCB with the bare AVR128DB48 MCU and the transceiver of your choice. The board's role is firmware-iteration speed, not BOM-level shipping.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Assembled in Pittsboro, North Carolina, USA. Components are sourced from global suppliers; final assembly, firmware, and QC happen in the NC workshop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm factor:\u003c\/strong\u003e Curiosity Nano development board; Arduino-style header layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=avr128db48devcan-development-board-curiosity-nano\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; certifications:\u003c\/strong\u003e available on request — \u003ca href=\"\/pages\/contact?product=avr128db48devcan-development-board-curiosity-nano\"\u003eopen a ticket\u003c\/a\u003e for the current scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eFull technical datasheet, installation guide, and warranty terms are available on request. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"\/pages\/contact?product=avr128db48devcan-development-board-curiosity-nano\"\u003eRequest datasheet\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=avr128db48devcan-development-board-curiosity-nano\u0026amp;type=quote\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44195446063301,"sku":"SAM-AVR128CAN-CN","price":49.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/AVR128DB48devCANcopy_84dd1436-18ea-4843-918e-363b4c01d8bb.jpg?v=1730679924"},{"product_id":"reel-winder-2-22r","title":"Reel Winder 2.22R","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eTabletop precision respooler for wire, filament, and coil winding\u003c\/h2\u003e\n\u003cp\u003eTwo independently vector-controlled motors coordinate spool rotation and traverse in closed-loop — the precision wind pattern that transformers, magnet-wire, medical tubing, and 3D-filament respoolers need without a floor-mount cable line. Single electrical connection, no shop air required, fits on a standard workbench.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhat it does that a single-motor winder can’t\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynchronized dual vector-control motors\u003c\/strong\u003e — one drives the take-up spool, one drives the traverse. Coordinated in closed loop, not via a mechanical linkage. No backlash, no drift in spool-to-traverse ratio.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e±1.5% length accuracy\u003c\/strong\u003e — consistent run-to-run, repeatable across recipes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5–2000 g closed-loop tension control\u003c\/strong\u003e — adjustable to the material; stable enough for magnet-wire, medical tubing, and natural-fiber respooling without kinking, twisting, or stretch damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 800 RPM\u003c\/strong\u003e winding speed; \u003cstrong\u003e2.5 kW\u003c\/strong\u003e drive power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo compressed air\u003c\/strong\u003e — unusual for a precision winder; eliminates the shop-air infrastructure dependency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecipe management\u003c\/strong\u003e — program a job once, recall and run repeatably. Reduces setup time on production runs of mixed SKUs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb-connected interface\u003c\/strong\u003e — remote job tracking and use metrics. Industry 4.0 ready.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTabletop footprint\u003c\/strong\u003e — fits on a standard workbench. Single electrical connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e emergency stop and fuse protection built in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive:\u003c\/strong\u003e two synchronized vector-control motors (closed-loop coordination of spool + traverse)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWinding speed:\u003c\/strong\u003e up to 800 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive power:\u003c\/strong\u003e 2.5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength accuracy:\u003c\/strong\u003e ±1.5% typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTension control:\u003c\/strong\u003e closed-loop, 5–2000 g range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial compatibility:\u003c\/strong\u003e metal wire, polyamide, nylon, natural fibers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir requirement:\u003c\/strong\u003e none\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e web interface for recipe management and use metrics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm factor:\u003c\/strong\u003e tabletop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e emergency stop, fuse protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional enhancements:\u003c\/strong\u003e length and diameter sensors, label-printing software, extended Wi-Fi range, custom bobbin and reel sizes — \u003ca href=\"\/pages\/contact?product=reel-winder-2-22r\"\u003erequest a quote\u003c\/a\u003e with your application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat materials can it wind?\u003c\/summary\u003e\n  \u003cp\u003eMetal wire, polyamide, nylon, and natural fibers are the four primary classes. The closed-loop tension range of 5–2000 g is wide enough to accommodate fragile filaments at the low end and heavier-gauge wire at the high end. For unusual materials, send us a sample and the target spool spec — we’ll confirm fit.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eDoes it need compressed air?\u003c\/summary\u003e\n  \u003cp\u003eNo. The 2.22R is one of the few precision winders in its class that does not require shop air. A single electrical connection is all that’s needed at install.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat about traverse repeatability vs. a single-motor + linkage winder?\u003c\/summary\u003e\n  \u003cp\u003eMechanical-linkage traverses introduce backlash and drift between spool rotation and the traverse position. The 2.22R uses two independently vector-controlled motors coordinated in closed loop — there is no mechanical linkage between them, and synchronization is enforced electronically. The result is a layered wind without the irregularity that drives rework on a linkage-driven machine.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eCan I run different jobs without re-tuning every time?\u003c\/summary\u003e\n  \u003cp\u003eYes — recipe management is built in. Program a job once with the desired tension, speed, and traverse pattern; recall and run it repeatably for production runs of mixed SKUs.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat does “web-connected” mean exactly?\u003c\/summary\u003e\n  \u003cp\u003eThe 2.22R has a web interface for recipe management and use metrics. You can pull job data, monitor production, and review use history from a network browser. Extended Wi-Fi range is an optional enhancement; reach out with your network requirements.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat spool sizes does it support?\u003c\/summary\u003e\n  \u003cp\u003eCustom bobbin and reel sizing is available as an optional enhancement — \u003ca href=\"\/pages\/contact?product=reel-winder-2-22r\"\u003erequest a quote\u003c\/a\u003e with your spool dimensions and we’ll confirm fit.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eIs this a quote-only or direct-buy SKU?\u003c\/summary\u003e\n  \u003cp\u003eDirect-buy via Shopify checkout is enabled. For volume orders, customization, international shipping, installation support, or training, we’ll switch you to a quote flow — \u003ca href=\"\/pages\/contact?product=reel-winder-2-22r\"\u003econtact us\u003c\/a\u003e with your scope.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat does install look like?\u003c\/summary\u003e\n  \u003cp\u003eSingle electrical connection. No air drop. Fits on a standard workbench — no floor space allocation, no rigging. Most installs are operator-trainable in a normal shift; we provide ticket-based support direct from NC.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat about a datasheet?\u003c\/summary\u003e\n  \u003cp\u003eA full technical datasheet with footprint, weight, electrical input, certifications, and tolerance specifications is available on request — \u003ca href=\"\/pages\/contact?product=reel-winder-2-22r\"\u003econtact us\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, North Carolina, USA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive:\u003c\/strong\u003e dual closed-loop vector-control motors; safety includes emergency stop and fuse protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-installed by:\u003c\/strong\u003e single-phase electrical termination by a qualified electrician where local code requires; the machine itself is operator-trainable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=reel-winder-2-22r\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; certifications:\u003c\/strong\u003e available on request — \u003ca href=\"\/pages\/contact?product=reel-winder-2-22r\"\u003econtact us\u003c\/a\u003e for the current scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-install\"\u003e\n\u003ch3\u003eSee it in action\u003c\/h3\u003e\n\u003cdiv class=\"install-video-wrap\"\u003e\n  \u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/rqAaZMn8U5E?rel=0\u0026amp;modestbranding=1\" title=\"Reel Winder 2.22R demo\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen loading=\"lazy\"\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eUser manual is available below. 1-year parts-and-labor warranty from \u003cstrong\u003edate of purchase\u003c\/strong\u003e. Datasheet, CAD files, and quote requests are routed through the contact form. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/Winder-2-22R-User-Manual_c0db67cc-9339-4ad6-b642-1156a734063a.pdf?v=1778368242\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=reel-winder-2-22r\"\u003eRequest datasheet\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=reel-winder-2-22r\u0026amp;type=quote\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44195524083909,"sku":"SAMRW2-22R001","price":13210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/reel-winder.jpg?v=1730684594"},{"product_id":"sam-can-bus-wire-tester-find-bad-wires-connectors-shorts-the-easy-way","title":"SAM CAN Bus Wire Tester (Model CWT4510x)","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\u003ch2\u003eBuilt for the layer scan tools cannot see\u003c\/h2\u003e\n\u003cp\u003eA modern vehicle is a rolling computer. Dozens of processors talk to each other over data buses the driver never sees and the technician rarely tests. When the conversation breaks down, the visible symptoms — a flickering light, an intermittent fault, a sensor that lies — almost never point at the actual cause.\u003c\/p\u003e\n\u003cp\u003eThe actual cause is usually the wire. Insulation cracks. A connector fills with moisture. Fretting corrosion raises the resistance of a contact under micromotion. A rodent removes ninety-nine percent of the jacket and leaves the last one percent doing structural work. Two conductors get pinched together just enough to corrupt one bit in a hundred — a fault that may only surface when the vehicle is moving.\u003c\/p\u003e\n\u003cp\u003eNone of this is exotic. All of it produces symptoms that scan tools cannot name, because scan tools read the network, not the cable underneath it.\u003c\/p\u003e\n\u003cp\u003eThe CAN Bus Wire Tester (Model CWT4510x) was built for that gap. It does not interpret data. It does not diagnose modules. It tests the wires — honestly, deterministically, and in a form a technician can carry to the vehicle and trust. No laptop, no subscription, no guess.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-how-it-works\"\u003e\u003ch3\u003eHow it works\u003c\/h3\u003e\n\u003cp\u003eThe tester actively transmits CAN frames in groups of 100 every two seconds and watches what the bus does in response. Used singly it confirms a single connection point is electrically sound. Used in pairs at opposite ends of the bus it verifies the entire run end to end — each unit chirps when it receives a packet from the other, so a healthy bus is audible.\u003c\/p\u003e\n\u003cp\u003eThe 16 × 2 OLED defaults to an error screen and the DISP button cycles five additional views: packet counters (transmitted, received, errored), recessive-state millivolts on CAN_H and CAN_L, dominant-state millivolts on CAN_H and CAN_L, a sent-data-fails counter, and a beep-on-receive toggle. Four colored status LEDs at the top — blue at power-on, then green \/ yellow \/ red — give a glanceable verdict from across the bay.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-error-codes\"\u003e\u003ch3\u003eSix error codes, plain English\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003cth\u003eMeans\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eAll Tests Pass\u003c\/td\u003e\n\u003ctd\u003eTransmitting and receiving cleanly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eNo Received Data\u003c\/td\u003e\n\u003ctd\u003eNo data from the partner tester for 5 s. Equivalent to Code 0 if working solo.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eCAN H Short to G\u003c\/td\u003e\n\u003ctd\u003eCAN_H reads 0 V while the tester is driving it to 3 V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eCAN L Short to G\u003c\/td\u003e\n\u003ctd\u003eCAN_L reads 0 V while the tester is driving it to 1 V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eTransmit Error\u003c\/td\u003e\n\u003ctd\u003eBus state does not match transmission. Wiring fault or another device on the bus.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eTermination Err\u003c\/td\u003e\n\u003ctd\u003eCAN_H and CAN_L recessive-state voltages differ. Termination or load imbalance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe full diagnostic procedure — including the worked example of isolating a wiring cut and a shorted module on the same bus by moving two testers along the run — is in the User Manual.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-failure-modes\"\u003e\u003ch3\u003eWhat it actually finds\u003c\/h3\u003e\n\u003cp\u003eCAN-bus wiring fails in a small number of well-defined ways:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector pin faults\u003c\/strong\u003e — corrosion, worn contact spot, defective crimp, surface oxidation, rodent or chemical contamination. Re-check threshold: under 100 mΩ contact resistance, infinite to ground or to other wires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector housing degradation\u003c\/strong\u003e — plastic loosens or over-tightens, contact area drifts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire faults\u003c\/strong\u003e — insulation cracking (a composite, not a chemical bond — once one component fails, the rest cascades), surface oxidation killing high-frequency response over distance, or mechanical damage: bend, compression, shear, lateral compression, pinch against an adjacent wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-wire termination oxidation\u003c\/strong\u003e — a ring terminal mechanically crimped without solder slowly raises its resistance. The reference shifts for every component sharing it, and the symptoms appear far from the actual fault.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe tester surfaces all of these as the six error codes above plus the millivolt and packet-fails counters. Manipulate the harness while the Sent Data Fails counter is visible and intermittents become countable instead of theoretical.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-specs\"\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTest method\u003c\/th\u003e\n\u003ctd\u003eActive transmit-and-listen, single tester or paired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e16 × 2 OLED with DISP button (6 screens)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStatus LEDs\u003c\/th\u003e\n\u003ctd\u003e4 test-status (blue → green \/ yellow \/ red), Tx + Rx at RJ-45, charge LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAudio\u003c\/th\u003e\n\u003ctd\u003eChirp on packet receive (toggle: hold DISP 4 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (pin 4 = CAN_H, pin 5 = CAN_L) + two 4 mm banana-jack terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003e120 Ω switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003eInternal rechargeable battery, or Mini-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation time\u003c\/th\u003e\n\u003ctd\u003eUp to 3 hours on battery; continuous on USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharge time\u003c\/th\u003e\n\u003ctd\u003e40 minutes from a Mini-USB charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003ePlastic handheld; IP24; optional shock-protection boot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e3.86 × 2.52 × 1.03 in (98 × 64 × 36 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.62 lb (260 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePhysical-layer agnostic — works on any 2-wire CAN: J1939, NMEA 2000, CANopen, ISOBUS, generic industrial CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-fit\"\u003e\u003ch3\u003eWho this is for, and who it isn't\u003c\/h3\u003e\n\u003ch4\u003eBuilt for\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFleet maintenance technicians on heavy trucks, buses, off-highway with J1939 chassis electronics\u003c\/li\u003e\n\u003cli\u003eMobile mechanics working without a full bay setup\u003c\/li\u003e\n\u003cli\u003eVehicle wiring specialists — harness repair, aftermarket installations\u003c\/li\u003e\n\u003cli\u003eHeavy equipment and agriculture — tractors, combines, forestry in harsh-wiring environments\u003c\/li\u003e\n\u003cli\u003eMarine electronics — NMEA 2000 in corroded saltwater harnesses\u003c\/li\u003e\n\u003cli\u003eIndustrial maintenance — CAN-based factory equipment, machine controls, CANopen networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eNot for\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid \/ EV high-voltage propulsion circuits — not rated for HV. Lethal hazard.\u003c\/li\u003e\n\u003cli\u003eEnergized systems in motion or capable of unintended actuation. Lock out before connecting.\u003c\/li\u003e\n\u003cli\u003eSafety-critical subsystems (SRS, pyrotechnic, ABS, ESC, fuel) without OEM lockout procedure.\u003c\/li\u003e\n\u003cli\u003eSubmersion, weather, explosive atmospheres — IP24, indoor \/ sheltered use.\u003c\/li\u003e\n\u003cli\u003eMessage-layer protocol decoding (J1939 DTC tracing, etc.) — use a CAN analyzer for that.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-docs\"\u003e\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eThe User Manual (Rev 2, May 2026) covers Quick Start for single and paired use, every screen and code, the LED conventions, the connector pinout, a worked diagnostic example, the Common Problems table, and the full Legal \u0026amp; Safety section. It is available below.\u003c\/p\u003e\n\u003cp\u003e1-year parts-and-labor warranty from date of purchase. Datasheet, CAD files, and quote requests are routed through the contact form. Ticket-based support direct from the manufacturer in Pittsboro, NC.\u003c\/p\u003e\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":45634837414085,"sku":"SAM-CWT4510X-D","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/SAMCANWiringTesterMain.png?v=1768458503"},{"product_id":"logic-probe-16-v2-2","title":"Logic Probe 16 v2.2 — 16-channel digital probe for Rigol MSO5000","description":"\u003csection class=\"prose-block\" id=\"section-overview\"\u003e\n\u003ch3\u003eLogic Probe 16 v2.2\u003c\/h3\u003e\n\u003cp\u003e16-channel logic-analyzer probe for Rigol MSO5000 series oscilloscopes. Converts 16 single-ended digital signals (D0–D15) to LVDS pairs over the scope’s 50-pin connector, so the MSO5000 sees a full digital-channel set with protocol decoding for SPI, I²C, UART, RS-232, and parallel buses.\u003c\/p\u003e\n\u003cp\u003eNothing to configure — plug it in, connect your signals, the scope sees 16 digital channels.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-specs\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 (D0–D15), single-ended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage:\u003c\/strong\u003e 0–5 V (3.3 V and 5 V logic compatible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreshold:\u003c\/strong\u003e ~1.4 V fixed (non-adjustable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDriver:\u003c\/strong\u003e TI SN65LVDS1 ×16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e +4 V from scope, no external supply needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB:\u003c\/strong\u003e 2-layer, ~60×80 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 50-pin to scope; 2×8 (or equivalent) probe-side\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"prose-block\" id=\"section-target\"\u003e\n\u003ch3\u003eFor engineers using Rigol MSO5000\u003c\/h3\u003e\n\u003cp\u003eDesigned for embedded-systems work where you already own a Rigol MSO5000 and need simultaneous analog + digital capture with protocol decoding. Common uses: Arduino, STM32, ESP32, Raspberry Pi, and FPGA bring-up.\u003c\/p\u003e\n\u003c\/section\u003e\n","brand":"SAM Controllers","offers":[{"title":"Complete kit","offer_id":46147085402309,"sku":"SAM-LP16-V22-KIT","price":160.0,"currency_code":"USD","in_stock":true},{"title":"Bare PCB","offer_id":46147085435077,"sku":"SAM-LP16-V22-PCB","price":30.0,"currency_code":"USD","in_stock":true},{"title":"Assembled Board","offer_id":46471469662405,"sku":null,"price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/logic-probe-16_c1906bd6-3f7a-4d40-afc9-fc861b87e6fc.jpg?v=1777503002"}],"url":"https:\/\/samcontrollers.com\/collections\/ready-to-ship.oembed","provider":"SAM Controllers Store","version":"1.0","type":"link"}