{"product_id":"compressor-controller-model-r","title":"Compressor Controller Model R","description":"\u003csection class=\"prose-block\" id=\"section-overview\"\u003e \u003ch3\u003eDigital control for reciprocating piston air compressors\u003c\/h3\u003e \u003cp\u003eReplace your drifting mechanical pressure switch with precision digital control. The Model R reduces energy consumption, removes moisture from your air, and tells you exactly what your compressor is doing, and when it needs maintenance.\u003c\/p\u003e \u003cp\u003eThe Compressor Controller Model R is a bolt-on digital control system for reciprocating piston air compressors over 2 HP. It replaces the factory mechanical pressure switch, a component that drifts up to 20% per year due to spring wear and temperature swings, with a drift-free digital pressure sensor and intelligent control logic.\u003c\/p\u003e \u003cp\u003eUsing continuous sensing of pressure, pump temperature, and ambient conditions, the controller manages start\/stop cycles, unloading, venting, and tank drainage with precision that mechanical switches and timers can't match. A Department of Energy funded study by Pecan Street demonstrated significant energy savings and a 100% reduction in compressed air moisture.\u003c\/p\u003e \u003cp\u003eInstallation is straightforward: the controller mounts in an enclosure, the digital pressure sensor threads onto the same port as your old pressure switch, and two wires connect to your compressor's contactor. Most installations are completed in hours, not days.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eAvailable in two models:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eR100 (CCR100).\u003c\/strong\u003e For single-pump compressors.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eR200 (CCR200).\u003c\/strong\u003e For duplex compressors, with automatic pump alternation to evenly distribute wear, plus a dual mode that runs both pumps together for double the flow when demand requires it.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSelect your model at the top of this page.\u003c\/p\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-features\"\u003e \u003ch3\u003eWhat it does\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003ePrecision pressure control.\u003c\/strong\u003e A 304 stainless steel digital pressure sensor (1% accuracy, long-term stability under 0.1% FS\/year) replaces the spring-and-diaphragm switch. No more drift, no more stuck switches, no more compressor running non-stop because debris jammed a spring.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSmart drain.\u003c\/strong\u003e Automatically calculates and drains moisture from the tank, achieving 100% air moisture reduction without wasting tank pressure or clogging. In many setups, this eliminates the need for a separate air dryer entirely.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eActive controllable start.\u003c\/strong\u003e Manages pump unloading during startup, reducing peak power draw and pump oil and water contamination while extending the life of critical components.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePerformance data logging.\u003c\/strong\u003e Tracks running hours, cycle counts, min\/max temperatures, sensor status, and maintenance timers, stored in onboard memory for the life of the compressor. A single-button interface with a 20×4 LCD display gives you the numbers you need for maintenance planning and asset management.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eInstant scalability.\u003c\/strong\u003e Pair multiple Compressor Controllers in a master\/slave configuration to cascade compressors for higher CFM or built-in redundancy.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eOptional outputs.\u003c\/strong\u003e Configurable control for drain valves, intercooler cooling fans (useful on two-stage compressors), and alarm devices.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-savings\"\u003e \u003ch3\u003eWhy it pays for itself\u003c\/h3\u003e \u003cp\u003eMechanical pressure switches, timer-based drains, and standalone dryers waste hundreds of dollars per year in a typical shop. The Model R addresses all three at once, reducing annual energy costs by up to 40%, with ROI typically achieved in under a year.\u003c\/p\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eCompressor HP\u003c\/th\u003e \u003cth\u003eAverage yearly savings\u003c\/th\u003e \u003cth\u003eAverage lifetime savings\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e5 HP\u003c\/td\u003e \u003ctd\u003e$709\u003c\/td\u003e \u003ctd\u003e$7,085\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e7.5 HP\u003c\/td\u003e \u003ctd\u003e$1,063\u003c\/td\u003e \u003ctd\u003e$10,628\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e10 HP\u003c\/td\u003e \u003ctd\u003e$1,417\u003c\/td\u003e \u003ctd\u003e$14,171\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e20 HP\u003c\/td\u003e \u003ctd\u003e$2,834\u003c\/td\u003e \u003ctd\u003e$28,341\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cem\u003eSavings estimates based on 8 hr\/day operation, $0.1668\/kWh, calculated using standard CAGI \/ U.S. DOE methodology. 10-year lifetime.\u003c\/em\u003e\u003c\/p\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-compare\"\u003e \u003ch3\u003eChoose your kit\u003c\/h3\u003e \u003cp\u003eEvery kit is ordered together with the controller you select above. The controller is the item on this page; the kit supplies the hardware around it, so what arrives is a complete package.\u003c\/p\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eKit\u003c\/th\u003e \u003cth\u003eWhat's included\u003c\/th\u003e \u003cth\u003eInstallation difficulty\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eController Only\u003c\/td\u003e \u003ctd\u003eController and all sensors\u003c\/td\u003e \u003ctd\u003eHigh. You source valves, enclosure, and fittings.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eComponents Kit\u003c\/td\u003e \u003ctd\u003eController, sensors, valves, enclosure, and fittings\u003c\/td\u003e \u003ctd\u003eModerate. Some technical skill required.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePre-Wired Kit\u003c\/td\u003e \u003ctd\u003eEverything in the Components Kit, pre-wired with harness\u003c\/td\u003e \u003ctd\u003eLow. Designed for straightforward installation.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003eAdd the controller to your cart and the kit step follows automatically, filtered to the model you chose. Professional installation is available through our installer network.\u003c\/p\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-box\"\u003e \u003ch3\u003eWhat's in the box\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eDigital Pressure Sensor (PRESS18200).\u003c\/strong\u003e 1\/8\" NPTM thread, 0 to 160 PSI working range, 250 PSI max.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePump Temperature Bolt-on Sensor (DTB360).\u003c\/strong\u003e One with R100 kits, two with R200 kits.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmbient Temperature and Humidity Sensor (DEDHT11).\u003c\/strong\u003e Digital, self-calibrating.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePower and alarm hardware.\u003c\/strong\u003e Buzzer alarm, rocker switch, and 110 to 220 VAC \/ 12 VDC power supply (200 to 277 VAC option available).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eParameter\u003c\/th\u003e \u003cth\u003eDetail\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eCompressor type\u003c\/td\u003e \u003ctd\u003eReciprocating piston, single or duplex, \u0026gt;2 HP, single or multi-stage\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower input\u003c\/td\u003e \u003ctd\u003e12 V DC (universal 95 to 277 VAC power supply included)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProcessor\u003c\/td\u003e \u003ctd\u003eATmega328p with real-time clock (±1 ppm) and onboard EEPROM data storage\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay\u003c\/td\u003e \u003ctd\u003e20×4 LCD, LED backlit (green or blue)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePressure sensor\u003c\/td\u003e \u003ctd\u003eDigital, factory laser-calibrated, 304 stainless steel, 0 to 160 PSI working \/ 250 PSI max\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTemperature sensing\u003c\/td\u003e \u003ctd\u003e−40 to +125 °C range, self-calibrating\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmbient sensing\u003c\/td\u003e \u003ctd\u003e20 to 90% RH, 0 to 50 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRelay outputs\u003c\/td\u003e \u003ctd\u003eNC-COM-NO, 10 A 250 VAC (use contactor or motor starter; relays do not drive the motor directly)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure rating\u003c\/td\u003e \u003ctd\u003eIP21. Indoor use, or sealed enclosure for outdoor.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperating temperature\u003c\/td\u003e \u003ctd\u003e−10 to +40 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions\u003c\/td\u003e \u003ctd\u003e7.1\"W × 5.4\"H × 2.3\"D (panel cutout 6.6\" × 4.7\")\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAssembled in\u003c\/td\u003e \u003ctd\u003eNorth Carolina, USA\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-notes\"\u003e \u003ch3\u003eImportant notes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eThe Compressor Controller does not replace safety valves or other critical safety components.\u003c\/li\u003e \u003cli\u003eIt does not modify your compressor's mechanical systems. It is a control add-on.\u003c\/li\u003e \u003cli\u003eRelay outputs require an appropriate contactor, power relay, or VFD. They are not designed to drive the compressor motor directly.\u003c\/li\u003e \u003cli\u003eUse only factory components. Third-party components may cause unintended operation and void the warranty.\u003c\/li\u003e \u003cli\u003eWarranty registration is required on all products.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection class=\"prose-block\"\u003e \u003ch3\u003eWho already installed it\u003c\/h3\u003e \u003cdiv class=\"logo-fader-block\"\u003e \u003cdiv class=\"logo-fader-block__copy\"\u003e \u003cp\u003eAutomotive paint and body shops, machine and CNC shops, cabinet and woodworking shops, fleet maintenance and tire shops, dental compressed-air rooms, light manufacturing, federal facilities, and dairy and farm operations: any continuous-duty reciprocating compressor where moisture, drift, or downtime cost money.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"logo-fader\" aria-label=\"Customers and partners\"\u003e \u003cdiv class=\"logo-fader__slot\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/sikorsky.png?v=1777433904\" alt=\"Sikorsky\" loading=\"lazy\"\u003e\u003c\/div\u003e \u003cdiv class=\"logo-fader__slot\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/firetron.png?v=1777433906\" alt=\"FireTron\" loading=\"lazy\"\u003e\u003c\/div\u003e \u003cdiv class=\"logo-fader__slot\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/usaf.png?v=1777433909\" alt=\"U.S. Air Force\" loading=\"lazy\"\u003e\u003c\/div\u003e \u003cdiv class=\"logo-fader__slot\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/whelen.png?v=1777433912\" alt=\"Whelen\" loading=\"lazy\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-integration\"\u003e \u003ch3\u003eHow it integrates\u003c\/h3\u003e \u003cp\u003eThe controller bolts onto reciprocating air compressors of any brand or age, single-pump or duplex, single-phase 120\/240 VAC or three-phase 208\/480 VAC. The pressure sensor (A) replaces the mechanical pressure switch and reads tank pressure to within 0.5 PSI across the operating range. The controller (E) drives the existing motor contactor (B) and steps in only when readings cross your set points, so the original starter, overload, and motor protection stay exactly where they are.\u003c\/p\u003e \u003cp\u003eThe smart drain (D) cycles on accumulated runtime, not a fixed timer, so it opens just long enough to clear condensate and closes before it bleeds tank pressure. The intercooler fan (F) is independently controlled when head temperature crosses threshold; the CompressorCity link (G) is a single-wire bus that lets multiple controllers share runtime, balance pump wear, and stand in for each other on failure.\u003c\/p\u003e \u003cp\u003eEvery variant uses the same operator interface, the same set-point structure, and the same diagnostic readout, so retraining is not part of the rollout. Installation runs about a working hour for a journeyman electrician with the existing panel still mounted; the supplied wiring harnesses bring labelled landings to every connection in the original control circuit.\u003c\/p\u003e \u003cp class=\"prose-block__figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/sam-2024-screenshot.png?v=1777502884\" alt=\"Compressor Controller integration diagram showing pressure sensor (A), motor contactor (B), drain valve (C, D), controller (E), intercooler fan (F), and CompressorCity link (G)\" loading=\"lazy\" width=\"1280\" height=\"800\"\u003e\u003c\/p\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-network\"\u003e \u003ch3\u003eScale instantly with Compressor-City\u003c\/h3\u003e \u003cp\u003ePair two or more controllers over a single one-wire link to share runtime, balance pump wear, and add N+1 redundancy without buying a duplex unit. The bus auto-discovers nodes on power-up: no addressing, no DIP-switch configuration, no commissioning step beyond running the wire.\u003c\/p\u003e \u003cp\u003eEach controller publishes its runtime hours, head temperature, current draw, and fault state; each subscribes to the same data from its peers. The lead unit handles primary demand; lag units cycle in proportionally so no single pump accumulates disproportionate hours. The result is a bank that lasts longer per unit and recovers from a maintenance event without dropping the room below set-point.\u003c\/p\u003e \u003cp\u003eOn failure the system fails over, not off. The next-healthiest unit takes the call within one duty cycle and the failed unit is held out until a technician acknowledges the fault. The same hardware that runs a single 5 HP shop compressor scales to a four-unit 200 HP industrial bank without changing firmware or panel layout, across any mix of single-pump and duplex units and any inverter or VFD configuration in front of them.\u003c\/p\u003e \u003cp class=\"prose-block__figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/linking-compressors.png?v=1777502883\" alt=\"Four reciprocating air compressors of different sizes, each with a SAM Compressor Controller mounted, demonstrating Compressor-City multi-unit pairing.\" loading=\"lazy\" width=\"1024\" height=\"640\"\u003e\u003c\/p\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-install\"\u003e \u003ch3\u003eInstallation\u003c\/h3\u003e \u003cdiv class=\"install-split\"\u003e \u003cdiv class=\"install-split__video\"\u003e \u003cdiv class=\"install-video-wrap\"\u003e \u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/taw5RJnbA9w?rel=0\u0026amp;modestbranding=1\" title=\"Compressor Controller installation walkthrough\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen loading=\"lazy\"\u003e\u003c\/iframe\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"install-split__steps\"\u003e \u003col\u003e \u003cli\u003e \u003cstrong\u003ePower off the compressor\u003c\/strong\u003e at the disconnect; verify the contactor is de-energized.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMount the enclosure\u003c\/strong\u003e within reach of the contactor (Pre-Wired editions: just bolt and run conduit).\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eWire the AC–DC supply\u003c\/strong\u003e from the supply side of the contactor to the controller's 12 V DC input.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLand the relay outputs\u003c\/strong\u003e on the contactor coil terminals (replacing the mechanical pressure switch).\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMount the sensors:\u003c\/strong\u003e pressure into the receiver tap; pump-head temp on the cylinder head; ambient near the intake.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSet DIP switches\u003c\/strong\u003e for °C\/°F, simplex\/duplex, drain on\/off, fan on\/off.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePower on, verify\u003c\/strong\u003e pressure setpoints and run a short cycle. The Quick Start Guide details every step.\u003c\/li\u003e \u003c\/ol\u003e \u003cp class=\"install-split__time\"\u003eTypical install: \u003cstrong\u003e2–3 hours\u003c\/strong\u003e for Pre-Wired editions, \u003cstrong\u003e3–5 hours\u003c\/strong\u003e for Components Kit.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-faq\"\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eWill this work on my Quincy \/ Ingersoll‑Rand \/ Champion \/ FS‑Curtis compressor?\u003c\/summary\u003e \u003cp\u003eYes. The controller is designed for any reciprocating air compressor 2 HP and up that uses a contactor-driven motor. It replaces the factory mechanical pressure switch and timer drain. Brand of the compressor doesn't matter; what matters is that it's reciprocating (not screw \/ rotary).\u003c\/p\u003e \u003c\/details\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eWhat's the difference between R100 and R200?\u003c\/summary\u003e \u003cp\u003eR100 (single pump) drives one compressor. R200 (dual pump) drives two compressors with lead\/lag alternation, balancing pump wear within ~5 minutes over service life. Pick R200 for duplex installations.\u003c\/p\u003e \u003c\/details\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eDo I need an electrician to install it?\u003c\/summary\u003e \u003cp\u003ePre-Wired editions arrive factory-tested with the panel ready to mount; a competent person can complete the install in 2–3 hours. The Components Kit is bolt-and-wire on standard duplex panels; if you're comfortable wiring a contactor, you can install it. Controller Only is for technically proficient users who source enclosure and valves independently.\u003c\/p\u003e \u003c\/details\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eWhat if my compressor is 230 V single phase?\u003c\/summary\u003e \u003cp\u003eThe controller runs on 12 V DC from the included AC–DC power supply (110 to 220 VAC input). The relay outputs are rated 10 A @ 250 VAC and switch the existing motor contactor. The controller does not carry motor current itself, so 230 V 1Φ or 240\/480 V 3Φ is fine.\u003c\/p\u003e \u003c\/details\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eCan I keep my existing pressure switch as a backup?\u003c\/summary\u003e \u003cp\u003eYes. The controller's relay outputs offer NO and NC contacts, so you can wire the mechanical switch in series as a fail-safe upper limit. Most installs disconnect the mechanical switch entirely once the controller is verified.\u003c\/p\u003e \u003c\/details\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eHow long does install take?\u003c\/summary\u003e \u003cp\u003eTwo to three hours for Pre-Wired editions. Components Kit installs typically run 3–5 hours including bolting the enclosure, mounting sensors, and wiring the existing contactor. The Quick Start Guide above walks the install step-by-step.\u003c\/p\u003e \u003c\/details\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eDoes the VFD edition qualify for utility rebates?\u003c\/summary\u003e \u003cp\u003eMany U.S. utilities run custom industrial energy-efficiency rebates that cover compressed-air controls, often paying per kWh saved. Confirm eligibility with your utility or program ally; the integrated 10 HP VFD pairs cleanly with most rebate programs.\u003c\/p\u003e \u003c\/details\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eCan I daisy-chain controllers across multiple compressors?\u003c\/summary\u003e \u003cp\u003eYes. Compressor City is a one-wire master\/slave link between two controllers. You get cheap N+1 redundancy and CFM scaling without buying a duplex unit.\u003c\/p\u003e \u003c\/details\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eWhat happens at the end of the warranty?\u003c\/summary\u003e \u003cp\u003e90-day parts and labor from \u003cstrong\u003edate of purchase\u003c\/strong\u003e. After that, replacement parts ship from Pittsboro, NC at standard pricing; ticket-based support continues at no charge. The controller has been in the field since 2017.\u003c\/p\u003e \u003c\/details\u003e \u003cdetails class=\"pdp-faq\"\u003e \u003csummary\u003eDo you ship internationally?\u003c\/summary\u003e \u003cp\u003eU.S. shipping ships from Pittsboro, NC. International orders are case-by-case; \u003ca href=\"\/pages\/contact?product=compressor-controller-model-r\"\u003erequest a quote\u003c\/a\u003e with destination and Incoterm.\u003c\/p\u003e \u003c\/details\u003e \u003c\/section\u003e \u003csection class=\"prose-block\" id=\"section-compliance\"\u003e \u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, North Carolina, USA.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eEnclosure:\u003c\/strong\u003e IP67 rated (Components Kit, Pre-Wired Bolt-on, and Pre-Wired + VFD editions).\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePressure sensor body:\u003c\/strong\u003e 304 stainless steel.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eField-installed by:\u003c\/strong\u003e the included Quick Start Guide is written for an industrial maintenance technician or competent installer; the User Manual covers full configuration.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eWarranty:\u003c\/strong\u003e 90 days parts and labor from date of purchase. Warranty registration is required on all products.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware. \u003ca href=\"\/pages\/contact?product=compressor-controller-model-r\"\u003eOpen a ticket\u003c\/a\u003e.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e \u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e \u003cp\u003e90-day parts-and-labor warranty from \u003cstrong\u003edate of purchase\u003c\/strong\u003e. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e \u003cdiv class=\"doc-buttons-row\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/Compressor-Controller-Brochure.pdf?v=1777340251\" target=\"_blank\" rel=\"noopener\"\u003eBrochure\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/R100-R200-Quick-Start-Guide.pdf?v=1777340254\" target=\"_blank\" rel=\"noopener\"\u003eQuick Start Guide\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/CCR100-CCR200-User-Manual.pdf?v=1777345909\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/CompressorController-VFD-Supplement.pdf?v=1777405142\" target=\"_blank\" rel=\"noopener\"\u003eVFD Supplement\u003c\/a\u003e \u003c\/div\u003e \u003cp\u003eQuestions before you buy? Call \u003ca href=\"tel:+19194428787\"\u003e(919) 442-8787\u003c\/a\u003e or visit \u003ca href=\"https:\/\/compressorcontroller.com\" target=\"_blank\" rel=\"noopener\"\u003eCompressorController.com\u003c\/a\u003e.\u003c\/p\u003e \u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"R100 (Single Pump) \/ Controller Only","offer_id":46584405426373,"sku":"CC-SP-CTRL","price":783.33,"currency_code":"USD","in_stock":true},{"title":"R200 (Dual Pump) \/ Controller Only","offer_id":46584405459141,"sku":"CC-DP-CTRL","price":967.21,"currency_code":"USD","in_stock":true},{"title":"R100 (Single Pump) \/ Components Kit","offer_id":46585303957701,"sku":"CC-SP-COMP","price":1282.66,"currency_code":"USD","in_stock":true},{"title":"R100 (Single Pump) \/ Pre-Wired Kit","offer_id":46585303990469,"sku":"CC-SP-PWBO","price":1732.66,"currency_code":"USD","in_stock":true},{"title":"R100 (Single Pump) \/ VFD Kit","offer_id":46585304023237,"sku":"CC-SP-VFD","price":1806.15,"currency_code":"USD","in_stock":true},{"title":"R200 (Dual Pump) \/ Components Kit","offer_id":46585304056005,"sku":"CC-DP-COMP","price":1516.42,"currency_code":"USD","in_stock":true},{"title":"R200 (Dual Pump) \/ Pre-Wired Kit","offer_id":46585304088773,"sku":"CC-DP-PWBO","price":1966.42,"currency_code":"USD","in_stock":true},{"title":"R200 (Dual Pump) \/ VFD Kit","offer_id":46585304121541,"sku":"CC-DP-VFD","price":1990.03,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/R100-Main-v3.png?v=1784871961","url":"https:\/\/samcontrollers.com\/products\/compressor-controller-model-r","provider":"SAM Controllers Store","version":"1.0","type":"link"}