{"product_id":"sam-sewage-pump-controller-oem","title":"SAM Sewage Pump Controller - OEM","description":"\u003csection class=\"prose-block prose-block--lead\"\u003e\n\u003ch2\u003eDigital sewage pump controller, scoped specifically for wastewater\u003c\/h2\u003e\n\u003cp\u003ePre-wired IP67 controller for sewage and wastewater pump installations. Distinct from the generic water-pump controller by dedicated float-switch fault-awareness logic and sewage-tuned reliability features. Optional remote \/ wireless monitoring available for installations where silent cycling into a failure is unacceptable.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-features\"\u003e\n\u003ch3\u003eWhy this controller vs. the conventional setup\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat-switch fault awareness\u003c\/strong\u003e — detects a jammed or failed float and flags it instead of silently cycling into a sewage backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry-run protection\u003c\/strong\u003e — stops the pump before an empty-sump run damages the impeller or seals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-time monitoring\u003c\/strong\u003e — continuous pump-operation tracking so faults surface in real time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 enclosure\u003c\/strong\u003e — rated for sewage-adjacent wet environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating-hour and cycle tracking\u003c\/strong\u003e — for maintenance planning and warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional remote \/ wireless monitoring\u003c\/strong\u003e — available as an add-on for lift stations and remote-site installs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-specs-prose\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm factor:\u003c\/strong\u003e pre-wired IP67 sewage pump controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure rating:\u003c\/strong\u003e IP67\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e dedicated sewage \/ wastewater installations — submersible or dry-pit, lift stations, septic and commercial sewage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat-switch logic:\u003c\/strong\u003e active fault-detection topology (vs passive continuity)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry-run protection:\u003c\/strong\u003e impeller \/ seal protection on empty-sump conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTracking:\u003c\/strong\u003e operating hours and cycle count\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Designed and assembled in Pittsboro, NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e full specifications (input voltage, pump compatibility, float-switch wiring, remote-monitoring protocol, dimensions) available on request — \u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\"\u003econtact us\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-faq\"\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eHow is this different from the standard Digital Water Pump Controller?\u003c\/summary\u003e\n  \u003cp\u003eThe sewage version adds dedicated float-switch fault-awareness logic and reliability features tuned for sewage \/ wastewater duty cycles. For wells, irrigation, and light-water duty, see the \u003ca href=\"\/products\/digital-water-pump-controller\"\u003eDigital Water Pump Controller\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWhat lift-station configurations are supported?\u003c\/summary\u003e\n  \u003cp\u003eThe base unit covers single-pump submersible and dry-pit sewage installations. For duplex (lead\/lag) lift stations, multi-float topologies, or remote \/ wireless reporting, contact us — specific configurations may be add-ons or custom.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eAre optional remote-monitoring features extra?\u003c\/summary\u003e\n  \u003cp\u003eYes — the live-store $1,485 base price includes the controller; remote \/ wireless monitoring is available as an add-on for installs that need it.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"pdp-faq\"\u003e\n  \u003csummary\u003eWill this work with my existing float switches?\u003c\/summary\u003e\n  \u003cp\u003eIt supports the typical mechanical and mercury-bulb float topologies used on sewage pumps. Confirm switch count and wiring with us before ordering — we'll match the harness.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block\" id=\"section-compliance\"\u003e\n\u003ch3\u003eCompliance \u0026amp; origin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Assembled in Pittsboro, North Carolina, USA. Components are sourced from global suppliers; final assembly, firmware, and QC happen in the NC workshop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e IP67 rated for sewage-adjacent wet environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e ticket-based support direct from the people who built the hardware — \u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\"\u003eopen a ticket\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; certifications:\u003c\/strong\u003e available on request — \u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\"\u003eopen a ticket\u003c\/a\u003e for the current scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\u003csection class=\"prose-block prose-block--docs\" id=\"section-docs\"\u003e\n\u003ch3\u003eDocumentation \u0026amp; warranty\u003c\/h3\u003e\n\u003cp\u003eFull technical datasheet, installation guide, and warranty terms are available on request. Ticket-based support direct from the manufacturer in NC.\u003c\/p\u003e\n\u003cdiv class=\"doc-buttons-row\"\u003e\n\u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\"\u003eRequest datasheet\u003c\/a\u003e\n\u003ca href=\"\/pages\/contact?product=sam-sewage-pump-controller-oem\u0026amp;type=quote\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"SAM Controllers","offers":[{"title":"Default Title","offer_id":44195258073285,"sku":"SAM-SPC-OEM","price":1485.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4106\/1317\/files\/sam-sewage-pump-controller.jpg?v=1730663091","url":"https:\/\/samcontrollers.com\/products\/sam-sewage-pump-controller-oem","provider":"SAM Controllers Store","version":"1.0","type":"link"}